? rhopoint components ltd , hurst green, oxted, surrey, rh8 9ax, uk t +44 (0) 870 608 1188 sales@rhopointcomponents.com www.rhopointcomponents.com technical datasheet temperature sensors ? read out via dc millivoltmeter or recorder ? 3.488v/(w/m 2 ) sensitivity ? supplied with calibration and temperature correction graph heat flux sensor type 2 0456-3 a quality high output heat flow sensor for precise measurement of heat transfer (loss or gain) through any surface material. applications include: checking insulation efficiency, wind tunnel studies, process control. dimensions in mm nominal sensitivity 3.48 8 v / ( w / m 2 ) maximum recommended heat flux 113k w / m 2 response time 0.4 second thermal capacitance 1021 j / ( m 2 -? c ) thermal impedance 0.002? c / ( w / m 2 ) maximum operating temperature 260?c specifications p r e c i s i o n i n e l e c t r o n i c s
|